| 100% Finland Origin | Vaisala | Correct Model: PTU3031B01A1BCPK1A0A1AAB1B0A |
| Correct: Humidity and Temperature Transmitter PTU3031B01A1BCPK1A0A1AAB1B0A | ||
| Pressure range: 500...1100 hPa, Probe cable length : 2 m cable, +80 °C, no additional temperature probe, Graphical display with keypad. Power supply: 10...35 VDC, 24 VAC | ||
| Output signal: RS232C + Analog outputs (Ch1 & Ch2, optional Ch3), Cable gland M20*1.5 | ||
| Pressure fitting: Barbed fitting for 1/8" hose | ||
| Humidity sensor: General purpose and high chemical concentrations - HUMICAP180R | ||
| Sensor protection: PPS plastic grid & stainless steel netting, spare: DRW010281SP | ||
| Probe installation accessories : Duct Installation kit, item 215003 | ||
| (PTU3031B1A1BCPK1A0A1AB1B0A) | ||
| 100% Finland Origin | Vaisala | Correct Model: PTU3031B01A1BCPK1A0A1AAB1B0A |
| Correct: Humidity and Temperature Transmitter PTU3031B01A1BCPK1A0A1AAB1B0A | ||
| Pressure range: 500...1100 hPa, Probe cable length : 2 m cable, +80 °C, no additional temperature probe, Graphical display with keypad. Power supply: 10...35 VDC, 24 VAC | ||
| Output signal: RS232C + Analog outputs (Ch1 & Ch2, optional Ch3), Cable gland M20*1.5 | ||
| Pressure fitting: Barbed fitting for 1/8" hose | ||
| Humidity sensor: General purpose and high chemical concentrations - HUMICAP180R | ||
| Sensor protection: PPS plastic grid & stainless steel netting, spare: DRW010281SP | ||
| Probe installation accessories : Duct Installation kit, item 215003 | ||
| (PTU3031B1A1BCPK1A0A1AB1B0A) | ||
| 100% Finland Origin | Vaisala | Moisture and Temperature Transmitter for Oil MMT162-C1DBB0AA60A1X |
| Transmitter type: Metal housing, NPT 1/2" thread | ||
| Analog output + RS-485 as standard: 4...20mA | ||
| Sensor protection: Stainless steel grid filter, standard | ||
| Cable for analog output and power supply: 2 m (6.6 ft) cable, M8 threaded connector, 90° angle | ||
| Package: Cardboard single package | ||
| User' s guide: Multilingual quick guide | ||
| 100% Finland Origin | Vaisala | Model: DM70F1B1A4B |
| Portable dewpoint meter | ||
| Indicator type :rechargable with all AC adapters | ||
| indicator Accessories: MI70LINK software with RS232 cable (MI70LINK) | ||
| Probe type: DMP74B -60…+20°C Td | ||
| Pro accessories: sampling cell DSC74 | ||
| Connection Cable to a Transmitter: no | ||
| Carrying Case : soft carrying case (MI70SOFTCASE) | ||
| 100% Finland Origin | Vaisala | Model: 213107SP |
| 10 m extension cable for the MI70 probes | ||
| 100% Finland Origin | Vaisala | Humidity and Temperature Transmitter HMT 334 H0A101BCAC100B01DFBAA1 |
| Cable length: 2 m cable for 232 mm probe | ||
| Parameters: RH+T | ||
| Display: Graphic LCD with backlight | ||
| Power supply: 10...35 VDC , 24 VAC | ||
| Cable bushings: Conduit fitting NPT1/2" | ||
| Humidity sensor type: General purpose HUMICAP180, spare: 15778HM | ||
| Sensor protection: Stainless steel grid, spare: HM47453SP | ||
| Installation kit for probe: Pressure fitting NPT 1/2" | ||
| 100% Finland Origin | Vaisala | Correct code: HMP110 C15A0C1A0 |
| (HMP110 - C15A0C5A0) | ||
| 0…5 V | ||
| CH1 RH | ||
| CH2 T -40…+80’C | ||
| Plastic grid with filter | ||
| HUMICAP180R sensor | ||
| No probe cable | ||
| Noted: Order code is C15A0C1A0 if no need cable | ||
| 100% Finland Origin | Vaisala | Vaisala DRYCAP® Dewpoint Transmitter DMT242 - A1A1A2J |
| DMT242-A1A1A2J | ||
| (DMT242) | ||
| consist of: | ||
| Td Range -80...+20C Td 4...20mA | ||
| No Cable, Connector Only | ||
| Pressure setting 1 bar abs | ||
| Sensor protection Stainless Steel Sintered Filter (37um) | ||
| No PC accessories | ||
| Sampling Cell, Swagelok 1/4" Male Connectors, DMT242SC2 | ||
| Useer’s guide in Japanese | ||
| The price includes a traceable calibration certificate for each unit. |